Neutrino Atlas
EN
← Back to the lesson

Neutrino Atlas · Worksheet · Lesson 2.7

How to read a neutrino measurement

Name:Class / course:Date:

Read the lesson on neutrino-atlas.com and answer the questions. Tick exactly one answer each time.
https://neutrino-atlas.com/learn/reading-a-measurement/

Part A – Beginner

  1. Which kind of uncertainty shrinks when an experiment collects more data?

    • A Systematic uncertainty
    • B Statistical uncertainty
    • C Both shrink equally
    • D Neither of them
  2. What does KATRIN's result “less than 0.45 electronvolts” mean?

    • A The neutrino mass is 0.45 eV
    • B The neutrino mass is exactly zero
    • C Data fit zero mass; larger values are excluded
    • D The mass lies between 0.45 and 1 eV
  3. What is the usual threshold for claiming a discovery?

    • A 1σ
    • B 2σ
    • C 3σ
    • D 5σ
  4. What caused OPERA's apparent faster-than-light neutrinos in 2011?

    • A A loose fibre-optic cable in the timing system
    • B A sterile neutrino
    • C Too few recorded events
    • D Neutrinos really travelling faster than light

Part B – Intermediate

  1. With 10,000 expected events, what is the relative statistical uncertainty?

    • A 10 %
    • B 1 %
    • C 0.1 %
    • D 100 %
  2. Why can KATRIN's best-fit mβ² be negative?

    • A Statistical fluctuations push the fitted value below zero
    • B Neutrinos have imaginary mass
    • C The Bayesian prior forces it
    • D Tritium decays backwards
  3. What combined significance did the LSND and MiniBooNE excesses reach?

    • A 3.8σ
    • B 4.2σ
    • C 5.2σ
    • D 6.0σ
  4. What does the look-elsewhere effect require of an analysis?

    • A Repeating the experiment at another site
    • B Adding systematics in quadrature
    • C Converting the local p-value into a global one
    • D Using a Bayesian prior

Part C – Expert (optional)

  1. For one parameter under Wilks' theorem, which Δχ² threshold gives 90 % CL?

    • A 1.00
    • B 2.71
    • C 4.61
    • D 5.99
  2. Why does Wilks' theorem fail for the mass ordering?

    • A The data are Poisson distributed
    • B Nuisance parameters are profiled
    • C Δm²21 is too small
    • D The orderings are discrete, non-nested hypotheses
  3. What one-sided p-value corresponds to Z = 5?

    • A 2.87 × 10⁻⁷
    • B 1.35 × 10⁻³
    • C 5 × 10⁻²
    • D 3.2 × 10⁻⁵
  4. Why is KATRIN's 0.45 eV limit stronger than its median expected limit?

    • A A Bayesian prior was used
    • B Systematics were neglected
    • C The best fit fluctuated downward
    • D The confidence level was raised to 95 %

Extra task

In three or four sentences, explain to someone without a physics background what this lesson is about.

Answer key for teachers

  1. B – Statistical uncertainty comes from random fluctuations in counts; a miscalibrated instrument, a systematic effect, stays wrong however much data is taken.
  2. C – An upper limit means no effect was seen: the data are compatible with zero, and masses above the limit are excluded at the stated confidence level.
  3. D – A 5σ deviation arises by chance only about once in 3.5 million tries; 3σ, about once in 740, counts only as evidence.
  4. A – The roughly 6σ effect was a systematic error, which no amount of extra data could have revealed.
  5. B – Poisson fluctuations are about √N; √10,000 = 100, which is 1 % of 10,000.
  6. A – If the true mass is zero or small, fluctuations often push the fit below zero; −0.14 eV² is such a case, and boundary-aware methods handle it.
  7. D – LSND reported 3.8σ and MiniBooNE 4.8σ; combined they reach 6.0σ, yet MicroBooNE found no matching νe excess.
  8. C – Scanning many energies or sky positions makes a large fluctuation likely somewhere, so a trials factor converts the local into a global p-value.
  9. B – For k = 1, Δχ² = 1, 4, 9 give 1, 2, 3σ and 2.71 gives 90 %; 4.61 and 5.99 are the k = 2 values for 90 % and 95 %.
  10. D – The NO–IO Δχ² is roughly Gaussian with mean ±T₀ and width 2√T₀, so √Δχ² is only a rough guide; pseudo-experiments are needed.
  11. A – p = 1 − Φ(Z) = ½ erfc(Z/√2); for Z = 3 this gives 1.35 × 10⁻³, for Z = 5 it gives 2.87 × 10⁻⁷.
  12. C – The best fit mβ² = −0.14 eV² lies below zero, so the limit is tighter than the sensitivity; collaborations therefore quote both.