The rate of spontaneous pulses a light sensor produces with no light present.

Thermionic emission from the photocathode, radioactivity in the glass and afterpulsing produce random hits. In large detectors these accidental hits set a floor on the usable trigger threshold. In sea-water telescopes, ⁴⁰K decays and bioluminescence add a comparable optical background.

In plain words

Even in total darkness a light sensor occasionally clicks, as if it had seen a photon. These false alarms are called dark counts, and how often they happen is the dark rate. A single click means little, but a detector with tens of thousands of sensors sees a steady drizzle of random hits that can imitate, or hide, a faint real signal.

In detail

In a photomultiplier the main source is thermionic emission: at room temperature the low work function of the photocathode lets electrons escape by heat alone. Further contributions come from radioactive ⁴⁰K and uranium in the glass and from afterpulses. In a silicon photomultiplier thermally generated carriers trigger avalanches, so the dark rate per area is much higher but falls steeply when the device is cooled.

N_random ≈ N_sensors · rdark · ΔtN_random: expected random hits in a trigger window; N_sensors: number of sensors; rdark: dark rate per sensor; Δt: window length

For illustration, 20,000 tubes at 20 kHz each produce about 80 random hits within a 200 ns window. A real low-energy event must stand clearly above that level, which sets a floor on the trigger threshold and the energy threshold.

In numbers

In the JUNO mass tests at about 22 °C, the Hamamatsu 20-inch tubes averaged about 15 kHz and the NNVT microchannel-plate tubes about 49 kHz. Silicon photomultipliers at room temperature typically show 10⁵ to 10⁶ counts per second per square millimetre. In deep-sea telescopes the decay of ⁴⁰K dissolved in sea water and bioluminescence add an optical background of a similar character, at the level of several kilohertz per 3-inch PMT.

Why it matters for neutrino physics

Dark noise is one reason why IceCube, whose sensors sit in ice at about −20 to −40 °C, enjoys a quiet baseline, and why JUNO-TAO and liquid noble detectors cool their silicon sensors.

Frequently asked questions

Is dark rate the same as background?

No. Dark counts are noise from the sensor itself, not physical particles. They add random hits to every event, while background events are real interactions that mimic the signal.

Mentioned in 6 pages

Last updated: · Editorial standard

Cite this page

Text

Neutrino Atlas (2026). “Dark rate”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/dark-rate/

BibTeX

@misc{neutrinoatlas2026termsdarkrate,
  title        = {Dark rate},
  author       = {{Neutrino Atlas}},
  year         = {2026},
  url          = {https://neutrino-atlas.com/terms/dark-rate/},
  note         = {Accessed 2026-11-22},
  language     = {english}
}