Neutrino Atlas
EN
  1. Terms
  2. Detection principles & detector technology
  3. Photodetection
  4. Photomultiplier tube (PMT)
  5. Photocathode coverage

Photocathode coverage

ConceptLevel 4 of 4Also called: PMT coverage, photo-coverage

The fraction of a detector's inner surface covered by light-sensitive PMT area.

Higher coverage collects more photons per MeV, lowering the energy threshold and improving resolution. Super-Kamiokande has about 40% coverage, while JUNO reaches about 78% to obtain its target energy resolution of 3%/√E(MeV), which is needed for mass-ordering sensitivity.

In plain words

Imagine trying to catch rain with buckets placed on a lawn. The more of the lawn you cover with buckets, the more water you collect. Photocathode coverage is the fraction of a detector's inner wall that is covered by the light-sensitive faces of its sensors.

In detail

The number of photoelectrons a detector collects per MeV of deposited energy is roughly proportional to the product of light yield, transparency, coverage and photon detection efficiency. Because the statistical energy resolution improves only with the square root of this number, doubling the coverage improves resolution by about 40%.

Npe ∝ Y · T · c · PDE, σE/E ≈ 1/√NpeNpe: photoelectrons per event; Y: photons emitted per MeV; T: fraction surviving attenuation; c: coverage; PDE: photon detection efficiency

In numbers

  • Super-Kamiokande: 11,146 tubes of 50 cm cover about 40% of the inner wall. After the 2001 PMT accident it ran for several years with about half the tubes (SK-II), roughly 19% coverage, before full coverage was restored in 2006.
  • Hyper-Kamiokande: about 20,000 tubes in a much larger tank give a lower geometric coverage than Super-Kamiokande, compensated by tubes with roughly twice the detection efficiency.
  • JUNO: 17,612 large PMTs packed as tightly as mechanics allow give an optical coverage above 75%. Together with a bright scintillator this is designed to yield well over a thousand photoelectrons per MeV and the target resolution of about 3% at 1 MeV.

Why it matters for neutrino physics

Coverage is a design trade-off between physics and money: PMTs and their electronics are a large share of the cost of a big detector. Low coverage is acceptable for GeV-scale atmospheric or beam events with plenty of light, but low-energy physics such as solar neutrinos and reactor spectra needs as much coverage as possible to push down the energy threshold and sharpen the energy resolution.

Frequently asked questions

Why not cover 100% of the wall?

Round tubes cannot tile a surface without gaps, and they need space for mounting, cabling and implosion shields. Above about 75–80% coverage, adding more becomes mechanically very hard and expensive.

Related terms

Mentioned in 11 pages

Last updated: · Editorial standard

Cite this page

Text

Neutrino Atlas (2026). “Photocathode coverage”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/pmt-coverage/

BibTeX

@misc{neutrinoatlas2026termspmtcoverage,
  title        = {Photocathode coverage},
  author       = {{Neutrino Atlas}},
  year         = {2026},
  url          = {https://neutrino-atlas.com/terms/pmt-coverage/},
  note         = {Accessed 2026-11-22},
  language     = {english}
}