Energy resolution
How precisely a detector measures energy, usually quoted as a fractional width such as 3%/√E(MeV).
Resolution is set by photon or charge statistics plus detector non-uniformities. It controls how sharply spectral features (oscillation wiggles, the 0νββ peak) can be resolved. Germanium reaches about 0.1% at 2 MeV, while JUNO aims for about 3% at 1 MeV.
In plain words
Even a perfectly calibrated detector does not give every 1 MeV event the same reading. Photons are counted one by one, and their number fluctuates; the response varies slightly from place to place. The result is a blur. Energy resolution measures how wide that blur is, and it decides whether two nearby energies can be told apart.
In detail
Resolution is quoted either as the standard deviation σ or as the full width at half maximum, FWHM = 2.355 σ for a Gaussian peak. For scintillator detectors the stochastic term usually dominates and is quoted as a percentage over √E: more collected light means a smaller a, which is why PMT coverage and photocathode quantum efficiency matter so much.
In numbers
- Germanium detectors used for double beta decay: a few keV FWHM at 2039 keV, about 0.1%.
- Bolometers such as CUORE: below 10 keV FWHM at 2527 keV.
- JUNO: designed for about 3% at 1 MeV, the best ever planned for a large liquid scintillator detector.
- Water Cherenkov detectors and neutrino telescopes: tens of percent at low energy, because far fewer photons are detected per MeV.
Why it matters for neutrino physics
- In neutrinoless double beta decay the signal is a narrow line at the decay energy. Good resolution keeps the tail of the allowed two-neutrino decay and other backgrounds out of the peak.
- In reactor oscillations the fast wiggles that carry mass ordering information are washed out unless resolution is a few percent.
- In direct mass measurements such as KATRIN, resolution near the beta spectrum endpoint limits the reachable mass.
Frequently asked questions
What is the difference between resolution and threshold?
The energy threshold is the lowest energy a detector can register at all; resolution is how precisely it measures energies above that threshold.
Why does resolution improve with energy?
Higher-energy events produce more photons or charge carriers. Their relative fluctuation shrinks as one over the square root of their number, so the stochastic term falls as 1/√E.
Related terms
People
On the timeline
Mentioned in 92 pages
Lessons 6
Comparisons 3
Milestones 10
- 1967 · Germanium detector searches for 0νββ
- 1987 · First laboratory observation of 2νββ decay
- 2005 · Mainz sets a 2.3 eV neutrino-mass limit
- 2020 · GERDA's final limit on 0νββ of germanium-76
- 2022 · CUORE sets a tonne-scale bolometer limit
- 2023 · IceCube observes neutrinos from the Milky Way
- 2023 · KamLAND-Zen 800 reaches 2.3 × 10²⁶ years
- 2024 · KamLAND-Zen's complete data set tightens the Majorana bound
People 8
Terms 63
- AMoRE
- Analysis & measurement
- Background
- Backgrounds & shielding
- Baseline
- CANDLES
- Cascade (shower) events
- Cherenkov radiation (detection)
55 more
- Cosmic neutrino background
- Cryogenic bolometers
- CUORE
- CUPID-Mo
- DANSS
- Detection principles & detector technology
- Detector technologies
- Double beta decay experiments
- Double-beta isotopes and Q-value
- Energy scale & nonlinearity
- Energy threshold
- Event topologies in neutrino telescopes
- EXO-200
- Exposure
- GRAND (Giant Radio Array for Neutrino Detection)
- Half-life limit & effective Majorana mass
- Heidelberg–Moscow Experiment
- High-purity germanium detectors
- Hybrid Cherenkov–scintillation detectors
- Ionisation charge collection
- JUNO
- JUNO-TAO
- KamLAND-Zen
- KATRIN
- Laboratorio Subterráneo de Canfranc (LSC)
- LEGEND
- Liquid scintillator detector
- MAJORANA Demonstrator
- Mass-ordering sensitivity
- NEMO-3 / SuperNEMO
- Neutrino energy reconstruction
- Neutrino-4
- NEXT
- Parametric resonance in the Earth
- Phonon / heat signal
- Photocathode coverage
- Photodetection
- Project 8
- PTOLEMY
- Quantum efficiency
- Rate vs shape analysis
- Relic neutrino detection methods
- Relic neutrinos
- Scintillation
- Signal mechanisms
- Statistics & inference
- Systematic uncertainty
- TEXONO
- Theia
- Tracking calorimeter
- Tritium beta endpoint method
- Two-neutrino double beta decay
- WATCHMAN / AIT-NEO
- Wave-packet decoherence
- Xenon time projection chamber
Last updated: · Editorial standard
Cite this page
Text
Neutrino Atlas (2026). “Energy resolution”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/energy-resolution/BibTeX
@misc{neutrinoatlas2026termsenergyresolution,
title = {Energy resolution},
author = {{Neutrino Atlas}},
year = {2026},
url = {https://neutrino-atlas.com/terms/energy-resolution/},
note = {Accessed 2026-11-22},
language = {english}
}