Neutrino Atlas
EN
  1. Terms
  2. Detection principles & detector technology
  3. Signal mechanisms
  4. Ionisation charge collection

Ionisation charge collection

ConceptLevel 3 of 4

Detecting a particle through the free electrons it knocks loose, drifting them to readout electrodes.

Charged particles ionise the medium they cross. In pure noble liquids or semiconductors the freed electrons can be drifted over long distances by an electric field and collected, giving millimetre-scale track images (time projection chambers) or excellent energy resolution (germanium diodes). Electronegative impurities such as oxygen and water must be kept at the parts-per-trillion level for long drifts.

In plain words

A charged particle racing through matter knocks electrons off the atoms it passes, leaving a trail of free electrons behind. If an electric field is applied, these electrons drift like leaves on a stream towards a collecting electrode. Recording where and when they arrive draws a picture of the track. Counting how many arrive measures the energy.

In detail

The number of freed charges is the deposited energy divided by the mean energy W needed per electron–ion or electron–hole pair:

N = E / WN: number of charge carriers; E: deposited energy; W: mean energy per pair, about 23.6 eV in liquid argon, 15.6 eV in liquid xenon, 3.6 eV in silicon and 2.96 eV in germanium.

Part of the charge recombines before it can drift away, which in noble liquids produces extra scintillation light. In a time projection chamber, the position on the readout plane gives two coordinates and the drift time gives the third. In liquid argon electrons drift at roughly 1.6 mm per microsecond in a field of 500 V/cm, so metres of drift take milliseconds. Electronegative impurities such as oxygen and water capture electrons, so their concentration must be kept below about 0.1 parts per billion.

Detectors that use it

Why it matters

Charge collection combines precise energy measurement with spatial imaging. Liquid argon images separate electrons from photons through the energy deposited at the start of a shower (electron–photon separation), which is essential for measuring CP violation in electron-neutrino appearance. Germanium's small W value gives many carriers per keV and therefore the sharp energy peaks needed for rare-decay searches.

Frequently asked questions

What is a time projection chamber?

A detector in which ionisation electrons drift through a uniform electric field to a readout plane. The readout gives a 2D image, and the drift time adds the third dimension.

Why are liquid argon detectors so pure?

A single impurity molecule can capture a drifting electron. For drift distances of metres, oxygen-equivalent contamination must be kept below about 100 parts per trillion.

Original papers

  1. ProposalW. J. Willis, V. Radeka, Liquid-argon ionization chambers as total-absorption detectors, Nucl. Instrum. Meth. 120, 221 (1974)

Related terms

Mentioned in 8 pages

Last updated: · Editorial standard

Cite this page

Text

Neutrino Atlas (2026). “Ionisation charge collection”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/ionisation-charge/

BibTeX

@misc{neutrinoatlas2026termsionisationcharge,
  title        = {Ionisation charge collection},
  author       = {{Neutrino Atlas}},
  year         = {2026},
  url          = {https://neutrino-atlas.com/terms/ionisation-charge/},
  note         = {Accessed 2026-11-22},
  language     = {english}
}