Semiconductor diodes of ultra-pure germanium with outstanding energy resolution.

HPGe diodes, operated cold, collect ionisation charge with resolution around 0.1% FWHM at 2 MeV. Crystals enriched to about 87–92% ⁷⁶Ge serve as both source and detector for neutrinoless double beta decay (Heidelberg–Moscow, GERDA, MAJORANA, LEGEND). Point-contact germanium detectors achieve sub-keV thresholds for reactor CEvNS (CONUS). Pulse-shape analysis separates single-site signals from multi-site gamma backgrounds.

In plain words

A germanium detector is a crystal of extremely pure germanium that works like a large diode. When radiation deposits energy inside, it frees many electrical charges, which a voltage collects. Because so many charges are created per unit of energy, the measurement is exceptionally precise: two gamma lines a few keV apart are easily resolved. That precision makes germanium the reference tool for gamma spectroscopy and a leading technology for rare-decay searches.

How the detector works

Germanium needs only about 3 eV to create an electron–hole pair, roughly ten times less than the energy needed to make a photoelectron in a scintillator. The crystal must be cooled to around 90 K or below, usually with liquid nitrogen or by immersion in liquid argon, to suppress thermal leakage current. Impurity levels around 10¹⁰ atoms per cm³ allow the whole crystal to be depleted and active.

In point-contact geometries the small electrode gives low capacitance and noise, so thresholds fall below 1 keV. The shape of the current pulse also shows whether energy was deposited at one point, as in double beta decay, or at several, as for a scattered gamma, a technique called pulse-shape discrimination.

In numbers

  • Energy resolution about 2.5 keV FWHM at 2039 keV, the Q-value of ⁷⁶Ge double beta decay.
  • Natural germanium contains about 7.8 % ⁷⁶Ge; detectors for double beta decay are enriched to about 86–92 %.
  • GERDA (2011–2019) set a limit of 1.8 × 10²⁶ years on the neutrinoless half-life with almost no background.
  • The MAJORANA Demonstrator reached 8.3 × 10²⁵ years with ultra-clean copper cryostats.
  • LEGEND-200 began data taking at Gran Sasso in 2023; LEGEND-1000 aims for half-lives beyond 10²⁸ years.

History

The Heidelberg–Moscow experiment at Gran Sasso operated about 11 kg of enriched germanium in the 1990s. Part of the collaboration claimed evidence for neutrinoless decay, a claim later excluded by GERDA.

Beyond double beta decay

Point-contact detectors with sub-keV thresholds detect reactor CEvNS. CONUS ran at the Brokdorf reactor and its successor CONUS+ reported a 3.7σ signal at Leibstadt in 2025.

Frequently asked questions

Why is the germanium enriched?

Enrichment increases the number of ⁷⁶Ge nuclei by a factor of about twelve without adding background, so the same detector mass is far more sensitive.

Why operate the detectors in liquid argon?

The argon cools the crystals, shields them and, by detecting its own scintillation light, vetoes background events that deposit energy outside the germanium.

Original papers

  1. Final resultM. Agostini et al. (GERDA Collaboration), Final Results of GERDA on the Search for Neutrinoless Double-β Decay, Phys. Rev. Lett. 125, 252502 (2020)DOI 10.1103/PhysRevLett.125.252502
  2. Final resultI. J. Arnquist et al. (Majorana Collaboration), Final Result of the Majorana Demonstrator's Search for Neutrinoless Double-β Decay in 76Ge, Phys. Rev. Lett. 130, 062501 (2023)DOI 10.1103/PhysRevLett.130.062501

Related terms

People

On the timeline

  1. 1967Germanium detector searches for 0νββ
  2. 2020GERDA's final limit on 0νββ of germanium-76
  3. 2025CONUS+ observes CEvNS at a nuclear reactor

Mentioned in 27 pages

Last updated: · Editorial standard

Cite this page

Text

Neutrino Atlas (2026). “High-purity germanium detectors”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/germanium-detectors/

BibTeX

@misc{neutrinoatlas2026termsgermaniumdetectors,
  title        = {High-purity germanium detectors},
  author       = {{Neutrino Atlas}},
  year         = {2026},
  url          = {https://neutrino-atlas.com/terms/germanium-detectors/},
  note         = {Accessed 2026-11-22},
  language     = {english}
}