Neutrino Atlas
EN
  1. Terms
  2. Detection principles & detector technology
  3. Event reconstruction & identification
  4. Particle identification (PID)
  5. Pulse-shape discrimination

Pulse-shape discrimination

ConceptLevel 4 of 4Also called: PSD

Separating particle types by the time profile of their scintillation or charge signal.

In scintillators and liquid argon, heavily ionising particles (alphas, nuclear recoils) excite more slow, triplet-state light than electrons. Comparing fast and slow components therefore separates them. In germanium detectors, pulse shapes separate single-site double-beta events from multi-site gamma backgrounds.

In plain words

Two particles can deposit the same energy and still leave signals of a different shape in time. Pulse-shape discrimination looks not at how big a pulse is but at how it rises and decays, the way one can tell a clap from a drumroll of equal loudness.

In scintillators and liquid argon

In scintillation, excited molecules or argon dimers relax through fast singlet and slow triplet states. Densely ionising particles, such as alphas, protons and nuclear recoils, populate relatively more slow states. In liquid argon the two components differ dramatically, roughly 6 ns against 1.5 µs, so the fraction of light in the first tens of nanoseconds separates electron recoils from nuclear recoils extremely well. In organic liquid scintillators the difference is smaller but still used: Borexino removes ²¹⁰Po alpha decays this way, and PROSPECT uses it to distinguish neutron captures and proton recoils from gamma rays.

In germanium detectors

In germanium detectors the shape of the charge pulse reveals how many places in the crystal released energy. The two electrons of double beta decay deposit their energy within about a millimetre (single-site), whereas a gamma ray usually scatters several times (multi-site). GERDA and LEGEND compare the current amplitude A with the energy E to reject multi-site and surface events.

Why it matters for neutrino physics

PSD is one of the cheapest forms of background rejection, because it needs only fast digitised waveforms rather than extra detector hardware. Together with an active liquid-argon veto it allowed GERDA to reach a background of about 5 × 10⁻⁴ counts per keV, kilogram and year at the ⁷⁶Ge decay energy, a key step towards the neutrinoless double beta decay half-life limits quoted today. In reactor and solar experiments it cleans the low-energy region where alpha contamination would otherwise dominate.

Frequently asked questions

Does pulse-shape discrimination work in water Cherenkov detectors?

Not in the same way. Cherenkov light is emitted promptly and has no slow component that depends on ionisation density. Water detectors instead identify particles from the geometry of the light, as in ring imaging.

Related terms

Mentioned in 17 pages

Last updated: · Editorial standard

Cite this page

Text

Neutrino Atlas (2026). “Pulse-shape discrimination”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/pulse-shape-discrimination/

BibTeX

@misc{neutrinoatlas2026pulseshapediscrimination,
  title        = {Pulse-shape discrimination},
  author       = {{Neutrino Atlas}},
  year         = {2026},
  url          = {https://neutrino-atlas.com/terms/pulse-shape-discrimination/},
  note         = {Accessed 2026-11-22},
  language     = {english}
}