2001 PMT implosion accident

ConfirmedLevel 4 of 4

A chain-reaction implosion that destroyed more than 6,700 of Super-Kamiokande's photomultipliers in November 2001.

During refilling, one PMT imploded and the resulting shock wave destroyed more than half the tubes. The detector resumed with half coverage (SK-II) and with PMTs protected by acrylic and fibreglass shields, and full coverage was restored in 2006 (SK-III). The accident led to shock-resistant PMT housings in later detectors.

What happened

In mid-2001 Super-Kamiokande was drained so that failed photomultipliers could be replaced. On 12 November 2001, while the tank was being refilled, one tube near the bottom imploded. Each 50-centimetre glass bulb is evacuated, so its collapse sent a pressure shock through the water. The shock broke neighbouring tubes, whose implosions added further shocks, and within seconds a chain reaction had swept the submerged part of the detector. According to the Kamioka Observatory, more than 6777 inner-detector tubes and about 1100 outer-detector tubes were destroyed.

The investigation concluded that the first tube had most likely been weakened by microfractures in its neck, possibly caused by workers standing on foam pads placed on the lower tubes during the replacement work.

Recovery

  • SK-II (October 2002 to October 2005): the 5182 surviving inner tubes were redistributed evenly, giving about 19 per cent photocathode coverage instead of about 40 per cent. Each tube was fitted with a clear acrylic front cover and a fibre-reinforced plastic casing, so that one implosion could no longer trigger others.
  • SK-III (from 2006): after new tubes were manufactured and installed, the inner detector was restored to 11,129 photomultipliers.

Why it matters

The K2K beam experiment resumed with the half-covered detector, and solar and atmospheric data taking continued, at a higher energy threshold for low-energy events. Super-K therefore never stopped producing physics for long. The accident changed how large water detectors are built: protective housings against shock waves are now standard for large photomultipliers in water, including the new tubes planned for Hyper-Kamiokande. At the time, the total repair was estimated at 15 to 25 million US dollars.

Frequently asked questions

Why could one implosion destroy so many tubes?

Water is almost incompressible, so the pressure pulse from one collapsing bulb travelled through the tank with little loss and struck the closely packed neighbouring tubes, each of which then imploded and added its own pulse.

How long did it take to restore full coverage?

About five years. Reduced-coverage operation started in October 2002 and full coverage returned in 2006.

People

On the timeline

  1. 2001Implosion chain destroys most Super-K photomultipliers

Mentioned in 8 pages

Last updated: · Editorial standard

Cite this page

Text

Neutrino Atlas (2026). “2001 PMT implosion accident”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/sk-pmt-accident/

BibTeX

@misc{neutrinoatlas2026termsskpmtaccident,
  title        = {2001 PMT implosion accident},
  author       = {{Neutrino Atlas}},
  year         = {2026},
  url          = {https://neutrino-atlas.com/terms/sk-pmt-accident/},
  note         = {Accessed 2026-11-22},
  language     = {english}
}