Delayed coincidence
Identifying an IBD event by a fast flash followed shortly by a second flash.
The positron annihilates immediately; the neutron thermalises and is captured after tens to hundreds of microseconds, releasing 2.2 MeV (hydrogen) or ~8 MeV (gadolinium). Requiring both signals close in time and space suppresses backgrounds by orders of magnitude.
In plain words
A detector deep underground still sees a steady drizzle of single flashes from natural radioactivity. An antineutrino caught by inverse beta decay is different: it produces one flash immediately and a second one shortly afterwards, close by. Asking for this pair, in the right order and with the right energies, is like recognising a friend by a knock followed by a second knock, rather than by any single noise.
In detail
- Prompt signal: the positron deposits its kinetic energy and annihilates, giving 1–10 MeV within nanoseconds.
- Delay: the neutron bounces off protons until it is thermal and is then captured. In pure scintillator or water this takes about 200 μs and releases a 2.2 MeV photon from hydrogen.
- With gadolinium loading at 0.1 % the capture time drops to about 30 μs and the capture releases a cascade of about 8 MeV, well above most natural radioactivity. Cadmium played this role in the Cowan-Reines experiment, and lithium-6 in PROSPECT.
Typical cuts require the delayed event within a few hundred microseconds and within roughly a metre of the prompt one. The rate of random pairings can be measured directly by opening off-time windows.
Remaining backgrounds
Some backgrounds mimic the pair: fast neutrons from cosmic muons, which first scatter on protons and then capture, and cosmogenic isotopes such as lithium-9 that emit an electron and a neutron. These are reduced by depth, muon vetoes and timing cuts after each muon. A related technique tags radon contamination through the bismuth-214 to polonium-214 decay pair, with a delay of about 164 μs.
Frequently asked questions
How much does the coincidence reduce background?
Typically by several orders of magnitude compared with single events, because two unrelated signals rarely occur in the same small time and space window.
Is delayed coincidence used only for antineutrinos?
No. Any process with a characteristic two-step decay can use it, for example tagging radioactive impurities in scintillator detectors.
Original papers
- DiscoveryC. L. Cowan Jr., F. Reines, F. B. Harrison, H. W. Kruse and A. D. McGuire, Detection of the Free Neutrino: a Confirmation, Science 124, 103 (1956)DOI 10.1126/science.124.3212.103
- MeasurementF. Reines, C. L. Cowan Jr., F. B. Harrison, A. D. McGuire and H. W. Kruse, Detection of the Free Antineutrino, Phys. Rev. 117, 159 (1960)DOI 10.1103/PhysRev.117.159
Related terms
People
On the timeline
Mentioned in 34 pages
Lessons 6
Milestones 4
Terms 17
Last updated: · Editorial standard
Cite this page
Text
Neutrino Atlas (2026). “Delayed coincidence”. Retrieved 22 November 2026, from https://neutrino-atlas.com/terms/delayed-coincidence/BibTeX
@misc{neutrinoatlas2026termsdelayedcoincidence,
title = {Delayed coincidence},
author = {{Neutrino Atlas}},
year = {2026},
url = {https://neutrino-atlas.com/terms/delayed-coincidence/},
note = {Accessed 2026-11-22},
language = {english}
}